ThunderTiles – Details and Specifications
High density glass wool core.
Sound blocking gypsum backing reduces sound transmission between rooms.
Fiberglass tissue micro mesh sealed with water based latex paint.
Absolute white finish for excellent light reflectance.
Available with trim or reveal edges.
REVEAL EDGE
TRIM EDGE
Primacoustic ThunderTiles combine high density 6lb glass wool with ½” gypsum board. The visible face features a decorative tissue with a painted latex finish. The acoustic tile is fully encapsulated in micromesh and edges are sealed to eliminate dusting during handling.
Designed to fit in standard T-bar ceilings. ThunderTile sizes are 24” x 24” (60cm x 60cm) and 24” x 48” (60cm x 121cm). Each size is available in a choice of flush-mount (trim edges) or drop-down (reveal edges) designs.
Superior acoustic performance coupled with exceptional sound blocking make the ThunderTile an ideal choice for controlling noise between offices, class rooms and entertainment areas and for controlling excessive ambiance which can affect speech intelligibility.
ThunderTiles have been independently tested for fire and smoke development to meet the rigorous ASTM E84 for use in the United States and CAN-UL S102 for use in Canada.
Physical Specifications
| Material: |
High-density glass wool (6 lbs/pcf) with gypsum backing |
| Dimensions: |
Available in two sizes:
23.75” (603mm) x 24” (603mm) x 1" (27mm)
47.75” (1213mm) x 23.75” (603mm) x 1" (27mm) |
| Facing: |
Fiberglass tissue painted with water based latex paint
|
| Colour: |
Absolute white finish |
| Installation: |
Exposed T-Bar grid, ¾” (15 ~ 24mm) |
| NRC: |
0.95 |
| CAC: |
38 |
| Fire-Resistant: |
Class-A: ASTM E84, CANULS102 (US and Canada)
Non-combustible according to GB9624-1997 |
| Thermal-Resistant: |
Greater than 0.5 (m2.k/w) |
| Humidity: |
Stable with up to 95% RH @ 120ºF (40°C) |
| Stability at 95% RH: |
No sagging, warping or delaminating |
| Moisture Rate: |
Less than 1% (JC/T670-2005) |
| Enviromental Impact: |
Tiles and packing are fully recyclable |
| Gypsum Source: |
Derived from quarries, not recycled |
| Safety: |
Limit of radionuclides in building materials
specific activity of 226Ra: Ira <1.0
specific activity of 226Ra, 232Th, 40K: Ir <1.3 |
| Test Data & Certificates: |
Reflectance
 |
Can UL Fire
 |
ASTM UL Fire
 |
ThunderTile 24 x 24
| Size |
Color |
Order Number |
Thickness |
Edge Treatment |
Qty. in Box |
Surface Coverage per Box |
24" x 24"
(60.3 x 60.3cm)
Coverage:
4 sq-ft per tile
(0.37 sq-meters) |
Absolute White |
P200-2424-00
|
1" (2.7cm) |
 |
8 |
32 sq-ft
(2.97 sq-meters) |
P201-2424-00
|
1" (2.7cm) |
 |
8 |
32 sq-ft (2.97 sq-meters) |
ThunderTile 48 x 24
| Size |
Color |
Order Number |
Thickness |
Edge Treatment |
Qty. in Box |
Surface Coverage per Box |
48" x 24"
(121 x 60.3cm)
Coverage:
8 sq-ft per tile
(0.74 sq-meters) |
Absolute White |
P200-2448-00
|
1" (2.7cm) |
 |
4 |
32 sq-ft
(2.97 sq-meters) |
P201-2448-00
|
1" (2.7cm) |
 |
4 |
32 sq-ft (2.97 sq-meters) |
Absorption Coefficients*
| Hertz |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
| StratoTile 20mm |
0.25 |
0.44 |
0.70 |
0.77 |
0.80 |
0.86 |
0.96 |
1.02 |
0.97 |
0.88 |
0.83 |
0.96 |
0.99 |
1.00 |
1.02 |
1.03 |
1.02 |
1.03 |
*Acoustic absorption based on StratoTile testing performed by Muller - BBM and
1/4 wavelegnth calculation.
Fire and Burn Performance for Broadway Panel Component
| Test |
Class |
Flame Spread |
Smoke Density |
Test Data |
| ASTM E 84-05 |
1 or A |
5 FSI |
10 SD |
 |
| CAN/UL-S102 |
1 or A |
2 FSC1 |
10 SD |
| BS 476 Parts 6 & 7 |
1 or A |
|
|
|
*Standard test methods for surface burning characteristics of building materials is used
to measure and describe the response of materials, products, or assemblies to heat and
flame under controlled conditions, but does not by itself incorporate all factors required for
fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual
fire condition. |