Accent Panels – Details and Specifications

Fabric covering available in three neutral colors
Formed, high density, semi-rigid glass wool panel for maximum absorption.
Micromesh tissue layer encapsulates glass wool fibers.
Available with square or beveled edges.
Hardened resin edges for clean architectural lines.

Accent panels are constructed of high density 6lb per cubic foot glass wool with resin hardened edges. This process works in tandem with the micromesh to fully encapsulate the glass wool to eliminate fibers from escaping. Panels are then covered in an acoustically transparent fabric in a choice of three colors for an architecturally attractive appearance.

Mounting is performed using a choice of Primacoustic Impalers: The Surface Impaler provides easy to use push-down impaling action for regular use while the Push-On Impaler is designed for high-speed precision installations where adhesive will be applied for safety.

Accent panels have been tested to meet stringent class-A/I fire ratings making them suitable for use in residential, commercial and industrial spaces and are offered in a variety designs to compliment various acoustical requirements.


Specifications

Core Material: Formed, semi rigid inorganic glass fibers
Density: 6.0 lbs. per cubic foot (96 kg/m3)
Fabric Facing: Acoustically transparent polyester tweed
Encapsulation: Micromesh on front and rear surface, resin treated edges
Absorption H2O: < 2% by weight @ 120°F (49°C), 95% relative humidity
Temperature: -20°F ~ 150°F (-29°C ~ 66°C)
Fire Rating: Class-A (ASTM E 84 / CAN/UL-S102 see details below)
Mounting: Galvanized steel impalers
*Absorption Coefficient:   125 250 500 1000 2000 4000 NRC
2" 0.45 0.83 1.07 1.00 1.01 1.00 0.89
Data Sheets &
Test Reports:
Data Sheet
2" Lab Test
 

*Notice: In our opinion, the short form sound absorption coefficient does not provide reliable data regarding the performance of a particular panel versus the problem frequency. This data is provided for comparison sake only. Please view the full frequency chart below to ensure that the panel you are considering will actually attenuate the frequencies you are attempting to absorb.

Panel Details

Order Number
(xx denotes color code)
Size Thickness Color Edge Treatment Qty. in Box Surface Coverage Image
Ark
F122-2415-xx
24" x 24 "
(61 x 61cm)
2"
(5.08cm)
Black=00

Beige=03

Grey=08
2 Panel: 3.14 sq-ft (0.29 sq-meters)

Box: 6.28 sq-ft (0.58 sq-meters)
Apex
F122-2416-xx
24" x 24" x 34"
(61 x 61 x 86cm)
Panel: 2 sq-ft (0.18 sq-meters)

Box: 4 sq-ft (0.37 sq-meters)


Absorption Coeffiecients

Hertz 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Broadway 2" 0.34 0.45 0.52 0.72 0.83 0.97 1.05 1.07 1.07 1.03 1.00 1.02 0.99 1.01 0.99 0.96 1.00 0.98

Testing performed by Riverbank Acoustical Laboratories. The test method conformed explicitly with the requirements of the ASTM Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method: ASTM C 423-02a and E795-05.


Fire and Burn Performance for Broadway Panel Component

Test Class Flame Spread Smoke Density Test Data
ASTM E 84 1 or A 15 155
CAN/UL-S102 1 or A 15 155

Test data provided by Bodycote Materials Testing Inc. This method, designated as ASTM E 84, "Standard Method of Test for Surface Burning Characteristics of Building Materials", is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment under actual fire condition.

Primacoustic is a division of Radial Engineering Ltd. Copyright 2010. All rights reserved.